US

sparQ Universal Library Quant Kit

Fastest qPCR-based library quantification in 40 minutes
Features & Benefits
  • Faster time to results – 50% shorter run time than traditional cycling protocols
  • Accurate, reliable quantification of NGS libraries of various sizes and GC-content
  • High amplification efficiency across a wide linear dynamic range
  • Stabilized, ready-to-use sparQ Universal Fast Mastermix to reduce pipetting steps
  • Superior run to run uniformity ensuring highly precise measurements

 

sparQ Universal Library Quant Kit is intended for molecular biology applications. This product is not intended for the diagnosis, prevention or treatment of a disease.

Product
Kit Size
Part Number
Price
Quantity
 
Product
Kit Size
Order Info
Price
Quantity

sparQ Universal Library Quant Kit

Request Sample
Kit Size:
Part Number:
Price:
Quantity:
Kit Size:  100 reactions
Part Number:  95210-100
Price:  $172.00
Add to Cart
Kit Size:  500 reactions
Part Number:  95210-500
Price:  $571.00
Add to Cart

Description

sparQ Universal Library Quant Kit provides rapid and accurate quantification of libraries prepared for sequencing on Illumina® NGS platforms. Accurate quantification of the number of amplifiable library molecules prior to loading onto a flow cell is a critical step in the NGS workflow and it ensures optimal cluster generation and cost-effective use of sequencing capacity. The sparQ Universal Library Quant Kit uses real-time quantitative PCR (qPCR) to specifically quantify the number of library molecules that possess the appropriate adapter tag at each end.

Request Sample


 

Companion NGS Calculator

For easy calculating the concentrations of unknown libraries.

Download

Details

Details

Contents

Name

Description

Volume

(100 rxn kit)

Volume

(500 rxn kit)

sparQ Universal Fast Mastermix

1.25x sparQ Universal Fast Mastermix containing primers that target the P5 and P7 Illumina adaptor sequences

1 x 1.6 ml

1 x 8 ml

sparQ DNA Standard 1

20 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 2

2 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 3

0.2 pM linear, dsDNA standard in 1x Library dilution buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 4

0.02 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 5

0.002 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 6

0.0002 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

High ROX Reference Dye

High ROX reference dye for use with “High ROX” instruments.

1 x 25 µl

1 x 250 µl

Library Dilution Buffer (10x)

10x concentrated buffer containing 0.1M Tris-HCl (pH 8.0), 1 mM EDTA, and stabilizers

1 x 1.5 ml

5 x 1.5 ml

 

Instrument Capability

Instrument Capability

ROX

  • Applied Biosystems 5700
  • Applied Biosystems 7000
  • Applied Biosystems 7300
  • Applied Biosystems 7700
  • Applied Biosystems 7900
  • Applied Biosystems 7900HT
  • Applied Biosystems 7900 HT Fast
  • Applied Biosystems StepOne™
  • Applied Biosystems StepOnePlus™

Low ROX

  • Applied Biosystems 7500
  • Applied Biosystems 7500 Fast
  • Stratagene Mx3000P®
  • Stratagene Mx3005P™
  • Stratagene Mx4000™
  • Applied Biosystems ViiA 7
  • Applied Biosystems QuantStudio™ (all models)
  • Douglas Scientific IntelliQube®

No ROX

  • Quantabio Q
  • BioRad CFX
  • Roche LightCycler 480
  • QIAGEN Rotor-Gene Q
  • Agilent AriaMx
  • Azure Cielo™
  • Other

Bio-Rad iCycler iQ systems

  • BioRad iCycler iQ™
  • BioRad MyiQ™
  • BioRad iQ™5
Customer Testimonials

Customer Testimonials

sparQ Universal Library Quant Kit

Quantification accuracy increased compared to the methods we used in the past! We will continue to use the sparQ kit to quantify our libraries before running samples on our Illumina system.

Research Assistant | University of Arkansas, Biomedical Engineering Department

Details

Contents

Name

Description

Volume

(100 rxn kit)

Volume

(500 rxn kit)

sparQ Universal Fast Mastermix

1.25x sparQ Universal Fast Mastermix containing primers that target the P5 and P7 Illumina adaptor sequences

1 x 1.6 ml

1 x 8 ml

sparQ DNA Standard 1

20 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 2

2 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 3

0.2 pM linear, dsDNA standard in 1x Library dilution buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 4

0.02 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 5

0.002 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

sparQ DNA Standard 6

0.0002 pM linear, dsDNA standard in 1x Library Dilution Buffer

1 x 25 µl

1 x 250 µl

High ROX Reference Dye

High ROX reference dye for use with “High ROX” instruments.

1 x 25 µl

1 x 250 µl

Library Dilution Buffer (10x)

10x concentrated buffer containing 0.1M Tris-HCl (pH 8.0), 1 mM EDTA, and stabilizers

1 x 1.5 ml

5 x 1.5 ml

 

Instrument Capability

ROX

  • Applied Biosystems 5700
  • Applied Biosystems 7000
  • Applied Biosystems 7300
  • Applied Biosystems 7700
  • Applied Biosystems 7900
  • Applied Biosystems 7900HT
  • Applied Biosystems 7900 HT Fast
  • Applied Biosystems StepOne™
  • Applied Biosystems StepOnePlus™

Low ROX

  • Applied Biosystems 7500
  • Applied Biosystems 7500 Fast
  • Stratagene Mx3000P®
  • Stratagene Mx3005P™
  • Stratagene Mx4000™
  • Applied Biosystems ViiA 7
  • Applied Biosystems QuantStudio™ (all models)
  • Douglas Scientific IntelliQube®

No ROX

  • Quantabio Q
  • BioRad CFX
  • Roche LightCycler 480
  • QIAGEN Rotor-Gene Q
  • Agilent AriaMx
  • Azure Cielo™
  • Other

Bio-Rad iCycler iQ systems

  • BioRad iCycler iQ™
  • BioRad MyiQ™
  • BioRad iQ™5

Resources

Customer Testimonials

sparQ Universal Library Quant Kit

Quantification accuracy increased compared to the methods we used in the past! We will continue to use the sparQ kit to quantify our libraries before running samples on our Illumina system.

Research Assistant | University of Arkansas, Biomedical Engineering Department

Welcome to the Quantabio webshop!

Please complete the new user account registration form

Once your account is setup, you'll be able to purchase any of the products on our site at any time with next day delivery for in stock products.

Product Finder

Select Your Assay

Starting Template

Assay Format

Detection Chemistry

Multiplexing (more than 3 targets)

Is gene-specific priming (GSP) required?

What current Reverse Transcriptase or cDNA kit are you using?

Select the group which contains your real-time PCR cycler

  • Applied Biosystems 7500
  • Applied Biosystems 7500 Fast
  • Stratagene Mx3000P®
  • Stratagene Mx3005P™
  • Stratagene Mx4000™
  • Applied Biosystems ViiA 7
  • Applied Biosystems QuantStudio™
  • Agilent AriaMx
  • Douglas Scientific IntelliQube®
  • Applied Biosystems 5700
  • Applied Biosystems 7000
  • Applied Biosystems 7300
  • Applied Biosystems 7700
  • Applied Biosystems 7900
  • Applied Biosystems 7900HT
  • Applied Biosystems 7900 HT Fast
  • Applied Biosystems StepOne™
  • Applied Biosystems StepOnePlus™
  • Quantabio Q
  • BioRad CFX
  • Roche LightCycler 480
  • QIAGEN Rotor-Gene Q
  • Azure Cielo 6
  • Azure Cielo 3
  • Other
  • BioRad iCycler iQ™
  • BioRad MyiQ™
  • BioRad iQ™5

Choose your application from the categories below

Products

I give Quantabio or an authorized Quantabio distributor permission to contact me for product updates and news.
* Required information